LPG is One of the Tyco Group Company which is Specialists in Fire Suppression System, It has Large range of Products for the Fire Suppression System, Such. FM® extiguishing agent is a clean gas widely accepted as substitute to Halon. FM® or heptafluoropropane (CF3CHFCF3), is suitable for the protection. damages to property and valuable equipment, likewise ensuring total safety to persons. LPG systems containing FMTM are designed to discharge within 10 .

Author: Kashakar Mukasa
Country: Australia
Language: English (Spanish)
Genre: History
Published (Last): 24 February 2018
Pages: 484
PDF File Size: 18.85 Mb
ePub File Size: 10.90 Mb
ISBN: 987-6-45252-756-7
Downloads: 62259
Price: Free* [*Free Regsitration Required]
Uploader: Nigul

The range of products we provide includes: Low expansion foams have an expansion rate less than 20 times.

FM Systems (HFCea) – LPG Fire Australia

The system can be operated automatically and manually. The small droplets create a large effective cooling surface area. Oxygen reduction systems reduce and maintain the oxygen concentration in a protected space to the llpg where flame cannot take hold yet human occupancy is possible. It is also electrically non-conductive.

Modern kitchens present a dangerous combination of high amounts of flammable oils and extreme sources of heat, creating an environment in which fire is a constant threat. Natural gas present in the atmosphere suitable for occupied areas at design concentration. As for the in-direct system, the tube acts as fire detection device, when it melts and loss pressure, the cylinder valve will open and release the extinguishing agent into the protected space via a separate set of pipe network and nozzle.

Upon flame impringement, the tube lg melts releasing the extinguishing agent with the direct system. The wet chemical fire extinguishing system is specifically designed and listed for the suppression of fires in commercial kitchen cooking appliances, plenums, hoods and ducts.

Therefore, damages compared to conventional sprinkler systems are minimized. Since carbon dioxide is a gas, there is no clean-up associated with a LPG CO 2 fire suppression system discharge LPG Co 2 System. Water Mist Systems Water based systems include low pressure water mist, high pressure water mist, medium velocity spray systems and high velocity spray systems. Electrically non-conductive, no residue to clean up after discharge and environmental friendly. It leaves no residue to lpv up after the discharge.

  ERVA DO DIABO CARLOS CASTANEDA PDF

LPG FM® High Pressure (42 bar) Clean Agent Fire Suppression Systems | VIC Engineering Sdn Bhd

When applied to a fire, CO 2 provides a heavy blanket of gas that reduces the oxygen level to a point where combustion cannot occur. Maximum reduction of damages by faster extinguishing.

LPG Water Mist System The Water Mist protection system optimizes the amount of water, maximizing the effective water volume through the distribution of droplets of very small size.

Available in cylinder or pump systems for both total flooding and local application. The Main advantages of FM systems are: LPG Carbon Dioxide fire protection systems are available for use in total flooding or local fire protection applications – making it an effective fire protection system for a wide variety of hazards.

As well, extraction hoods capture a large amount of grease that deposits in the interior of the hoods, the fans, and ducts, providing possible ways to initiate or propagate a fire. Fire Fighting Foam Systems. Application systems for risks involving flammables Class B. Specially suitable for storage areas requiring low temperatures. Every type of foam has its application.

The discharge of an extinguishing fixed system by gas generates an increase in the room pressure, depending on parameters such as flow, concentration, or leakage area that can lead to structural damage in the protected area. The Novec fire protection fluid extinguishes fire primarily by removing heat from the fire.

Most of the inert systems discharge directly from the cylinder with the charging pressure or bar. Protection Systems in occupied areas. As a general rule, extinguishing concentration is achieved when oxygen concentration in the protected space is reduced from its usual level of Sometimes we forget how important it is to have a suitable extinguishing system available until an accident occurs.

  ANCHIMERIC EFFECT PDF

Various fire fighting foam systems available with UL Underwriters Laboratories listing; FM Factory Mutual approval; major marine classification type approval.

LPG FM-200® High Pressure (42 bar) Clean Agent Fire Suppression Systems

Suitable for the protection of computer rooms, archives and electrical equipment. The water mist system optimises the quantity of water used through the distribution of very small droplets to achieve maximum cooling effect. Allow for real operation tests and check the extinguishing system accordingly. LPG Fire Australia is a dedicated team of fire protection professionals across Australia with a combined years experience in Special Hazard fire protection systems.

This system is commonly used for the protection of electrical cabinest fm20 machinery with casing. Specialist in Fire Extinguishing System. Carbon dioxide gas has a high rate of expansion, which allows a LPG CO 2 fire protection system to work fast. CO 2 or Carbon dioxide is a colorless, odorless, electrically non-conductive gas Electrically non-conductive and extinguishes fire primarily by absorbing heat.

Class B foams are designed for flammable liquids. Class A foams lower the surface tension of the water which assists in the wetting and saturation of Class A fuels with water, aiding fire suppression and prevent reignition.

Because of its high vapor pressure at ambient temperature 41 bar 20 o CFE TM does not require to be pressurized with nitrogen. It leaves no oily residue or deposits to damage software, data files or communications equipment, meaning post-discharge clean up time and costs are minimal.